Gas Logs Chosen From the Firebox Numbers on Your Report
Request Gas Logs
Fill in the form with the address and what the visit is for. Our callback confirms the scope and the price from our list.
What the Visit Records
A gas log set is only as safe as the fireplace under it. We inspect the firebox, damper and flue first and record what we find. Then we help you choose a vented or vent-free set that suits the room and the opening, fit the burner, connect it to the existing gas line and test flame and draft with you watching. Pricing depends on the set and the gas work and is given in writing.
Vented and Vent-Free, and What Your Fireplace Can Take
A log set is the lightest way to put gas into a wood fireplace: ceramic logs laid over a gas burner pan, lit with a match, a key, a switch or a remote depending on the set. It is a fire to look at more than a heater. There are two families. Vented sets make the larger, yellow flame most people picture, and because their exhaust leaves through the flue, a clamp holds the damper part way open, which stops it from ever closing over burning gas. Vent-free sets burn a cleaner blue flame that puts its heat and its exhaust into the room, so each one is rated for a minimum room size and carries an oxygen sensor that cuts the gas when indoor air runs low. Rules on vent-free sets are tight in California, so the report says plainly which family your fireplace and room can take.
Choosing a set starts from the fireplace report. Before a log set goes in, the flue has to be clear and sound, the damper has to work well enough for the clamp to hold it, and the firebox has to be large enough for the set with the clearance its maker asks for. We measure the firebox and write the numbers on the report, so you can compare sets by their listed fit instead of by photos. Undersized sets sit like a toy in a deep brick firebox, and oversized ones pack the opening and throw heat at the mantel. With the numbers on paper, the showroom choice comes down to the look you like among sets that will actually fit your fireplace. It also saves a second trip to swap a set that turned out too big.
The Gas Supply and the Cost
Many older fireplaces in Signal Hill and Long Beach already have a gas supply ending at a valve near the hearth, left from an earlier conversion or put in long ago to help light wood fires. We check it for size, condition and a working shut-off before connecting to it. If no supply reaches the fireplace, a plumber runs one and we time our fitting around that. Gas log sets carry no fixed figure on our list; the cost is the set itself, which you choose, plus the fitting work, which mostly depends on that gas supply. The quote shows the two parts on separate lines, so you can change the set without the fitting price moving and see what each choice adds. A stiff or weeping valve at the hearth goes on the quote as well.
If heat matters more to you than the look, compare a log set with a sealed gas insert before deciding. On our list an insert fitted into the firebox and connected sits between $2,750 and $5,550, far above a log set, but it heats the room where a log set mostly decorates it. We can put both options on one quote so the trade is in front of you in figures. For a fireplace with a damaged flue or a damper that will not hold a clamp, the report lists the repair that has to come first, because neither a log set nor an insert should go into a chimney that cannot carry its exhaust safely to the top. Fixing that first protects whichever of the two options you finally settle on.
How Tierney Chimney Experts Reports
Three Labels
Safe to use, monitor, or repair before use
Urgent Items First
Anything unsafe sits on page one
Separate Quote
Repair prices kept off the report itself
Matching Copies
One version sent to each person you name
Where we book gas logs
Pick a city to read how this visit plays out there: the housing we usually record, the weather behind the findings, and what the write-up includes.
CA
Signal Hill gas logs report
Late redevelopment left the hill younger than the Long Beach streets around it, and just 49% of homes predate 1980. Its newer condos and hilltop houses often run a factory-built metal firebox, and your report captions the flue, cap and chase top photo by photo.
Open city pageCA
Long Beach gas logs report
Here 79% of homes predate 1980 and 34% predate 1950. After 1933 a lot of brick stacks were repaired or rebuilt, so the report notes which sections look original, which look newer, and what each photographed crack means.
Open city pageCA
Lakewood gas logs report
Fireplace or not? Some tract models never had one. If yours does, its brick or block stack probably went up with the house, and the report pictures that crown, mortar and firebox; 80% of homes here are detached.
Open city pageCA
Gardena gas logs report
Postwar chimneys here, brick or block, were often converted to gas logs later on. Our report answers one question up front: does the flue still suit that setup, shown with photos of the damper, the logs and the stack interior.
Open city pageOther Services With Photo Records
Chimney Sweep
Flue brushed and vacuumed, then photographed clean, with the creosote stage and any follow-up items written into a note you keep.
See the visit →Chimney Inspection
A Level 1 read of the chimney from hearth to crown, delivered as a photo report with every finding sorted by urgency.
See the visit →Chimney Repair
Repairs scoped from inspection photos, so every line of the quote points back to a picture of the fault it fixes.
See the visit →Fireplace Inspection
The room side of the system examined and written up: firebox, damper, hearth, surround and the distance to nearby trim.
See the visit →Fireplace Repair
Firebox, hearth and damper repairs priced line by line from report photos and photographed again once finished.
See the visit →Chimney Level 2 Inspection
A recorded camera pass up the whole flue plus attic and roof checks, delivered as video, still frames and a written report.
See the visit →Chimney Cap Installation
Sized to your flue tile, the new cap is shown in roof photos taken before and after so the report shows the change.
See the visit →Chimney Flashing Repair
Roof joint leaks traced, documented and resealed with new step and counter flashing let into the brick.
See the visit →Chimney Masonry Repair
Open joints, flaked faces and loose top courses repaired, with a photo log that follows each area from start to finish.
See the visit →Chimney Rebuilds
When repair no longer holds, the failed part of the stack comes down and is rebuilt, with the scope drawn from photos.
See the visit →Fireplace Cleaning
Soot and ash cleared from the firebox and surround, with the bare brick and joints photographed once they can be seen.
See the visit →Gas Fireplace Cleaning
A gas unit serviced inside and out, with a carbon monoxide level and the vent condition written on the service sheet.
See the visit →Gas Fireplace Repair
Faults tested with a meter, written up with each reading, and repaired once you approve the part and its price.
See the visit →Fireplace Remodel
Surround, hearth and mantel changes planned after an inspection, so the firebox behind the new face is sound.
See the visit →Fireplace Inserts
An insert fitted after a measured inspection of the firebox and flue, venting through a stainless liner to the top.
See the visit →Pellet Stove Repair
A pellet stove run through a start cycle, each fault logged against the part behind it, and the vent pipe inspected.
See the visit →Wood Stove Repair
Door seals, baffles, firebrick and combustors replaced, with the stove pipe and its chimney connection written up.
See the visit →Chimney Seismic Retrofit
Older brick stacks rated for quake risk, then braced, strapped or rebuilt lighter above the roof, with options laid out from photos.
See the visit →Chimney Crown Repair
Cracked or thin crowns sealed or recast, with the top of the stack photographed before and after for the report.
See the visit →Dryer Vent Cleaning
Lint cleared from the dryer duct, airflow measured at the outlet, and the duct route written up with any damage.
See the visit →Chimney Liner Installation
A stainless flue liner matched to the appliance's vent size, run the full height and recorded on camera when done.
See the visit →Chimney Leak Repair
Leaks traced to their source with photos, then repaired at whichever crown, cap, flashing or brick let the water in.
See the visit →Chimney Waterproofing
Breathable repellent applied to sound brick once repairs are done, with the treated faces logged in the report.
See the visit →Chimney Damper Repair
Sticking, warped or rusted dampers repaired or replaced, with their condition photographed in the report.
See the visit →Chimney Chase Cover
Chase tops that hold water rated in the report, then replaced with a custom stainless cover once the framing is checked.
See the visit →