Fireplace Inserts Chosen From the Firebox Measurements, Not a Brochure
Request Fireplace Inserts
Fill in the form with the address and what the visit is for. Our callback confirms the scope and the price from our list.
What the Visit Records
An insert turns an open fireplace into a sealed heater. We measure the firebox, check the damper area and the flue, and only then suggest models that fit without cutting the masonry. Each insert vents through a stainless liner to the top of the chimney. Fitting a gas insert into a fireplace already in the house runs $2,750 to $5,550, and the scope sheet names the model, liner size and gas work.
Whether an Insert Fits Is a Measuring Question
An insert is a heater built to sit inside a fireplace you already have, closed at the front with glass and vented through a new liner up the old chimney. Whether one will fit is a matter of numbers, so our insert work begins with the inspection report. The firebox has to be deep and wide enough for the unit, with room for the air space around it. Our report also checks the flue: it needs to be solid enough to hold a liner, with the height the insert's venting rules ask for. The damper and its frame must leave space for the liner to pass, or come out. We write those dimensions down, then show you inserts that fit, gas or wood, with their sizes listed beside the firebox measurements so you can see the margin for yourself instead of taking our word for it.
Gas inserts are the usual choice around Signal Hill and Long Beach. They start from a switch or a remote, need no wood stacked anywhere, and are not held back on the winter days the air district marks as no burn for wood. Wood inserts give a real fire and more heat for the fuel money, and suit owners with a supply of dry wood who are fine working around that calendar. Either way, a sealed insert turns a fireplace that mostly warms the sky into one that warms the room, because it controls the air that feeds the fire and keeps the heat in the house. The report notes which type your chimney can take and anything that has to be repaired before the insert goes in, such as a cracked smoke chamber or a crown that is letting water down the flue.
Price, Paperwork and the Alternatives
On our list, a gas insert set into the firebox and connected costs between $2,750 and $5,550. The spread comes from the unit you choose, how tall the chimney is, how far the gas supply has to travel and the trim panel around the face. Wood inserts have no published figure because the unit, the liner and the hearth work vary more. For a room that has never had a fireplace, a direct vent gas unit framed into a wall costs $4,450 to $8,900. Whatever the choice, the quote lists the model, the liner size and length, the gas work and the finish, so the figure can be checked line by line against any other quote you collect for the same fireplace. Any change to that list is agreed with you first.
The paperwork from an install lists the model and serial number, the liner size, the clearances we measured and the install date. Keep it with the house papers. A buyer's inspector or an insurer asking about the insert can be handed one page instead of a guess. If an insert is more than you need, a vented gas log set gives the look of a fire with far less work, though much less heat. And if the flue turns out too damaged for a liner without repair, the report says what that repair is before any unit is ordered, so you never end up with a heater in a box and a chimney that cannot take it. Owners in Lakewood and Gardena with small fireboxes often find a slim gas model is the one that fits.
How Tierney Chimney Experts Reports
Three Labels
Safe to use, monitor, or repair before use
Urgent Items First
Anything unsafe sits on page one
Separate Quote
Repair prices kept off the report itself
Matching Copies
One version sent to each person you name
Where we book fireplace inserts
Pick a city to read how this visit plays out there: the housing we usually record, the weather behind the findings, and what the write-up includes.
CA
Signal Hill fireplace inserts report
Late redevelopment left the hill younger than the Long Beach streets around it, and just 49% of homes predate 1980. Its newer condos and hilltop houses often run a factory-built metal firebox, and your report captions the flue, cap and chase top photo by photo.
Open city pageCA
Long Beach fireplace inserts report
Here 79% of homes predate 1980 and 34% predate 1950. After 1933 a lot of brick stacks were repaired or rebuilt, so the report notes which sections look original, which look newer, and what each photographed crack means.
Open city pageCA
Lakewood fireplace inserts report
Fireplace or not? Some tract models never had one. If yours does, its brick or block stack probably went up with the house, and the report pictures that crown, mortar and firebox; 80% of homes here are detached.
Open city pageCA
Gardena fireplace inserts report
Postwar chimneys here, brick or block, were often converted to gas logs later on. Our report answers one question up front: does the flue still suit that setup, shown with photos of the damper, the logs and the stack interior.
Open city pageOther Services With Photo Records
Chimney Sweep
Flue brushed and vacuumed, then photographed clean, with the creosote stage and any follow-up items written into a note you keep.
See the visit →Chimney Inspection
A Level 1 read of the chimney from hearth to crown, delivered as a photo report with every finding sorted by urgency.
See the visit →Chimney Repair
Repairs scoped from inspection photos, so every line of the quote points back to a picture of the fault it fixes.
See the visit →Fireplace Inspection
The room side of the system examined and written up: firebox, damper, hearth, surround and the distance to nearby trim.
See the visit →Fireplace Repair
Firebox, hearth and damper repairs priced line by line from report photos and photographed again once finished.
See the visit →Chimney Level 2 Inspection
A recorded camera pass up the whole flue plus attic and roof checks, delivered as video, still frames and a written report.
See the visit →Chimney Cap Installation
Sized to your flue tile, the new cap is shown in roof photos taken before and after so the report shows the change.
See the visit →Chimney Flashing Repair
Roof joint leaks traced, documented and resealed with new step and counter flashing let into the brick.
See the visit →Chimney Masonry Repair
Open joints, flaked faces and loose top courses repaired, with a photo log that follows each area from start to finish.
See the visit →Chimney Rebuilds
When repair no longer holds, the failed part of the stack comes down and is rebuilt, with the scope drawn from photos.
See the visit →Fireplace Cleaning
Soot and ash cleared from the firebox and surround, with the bare brick and joints photographed once they can be seen.
See the visit →Gas Fireplace Cleaning
A gas unit serviced inside and out, with a carbon monoxide level and the vent condition written on the service sheet.
See the visit →Gas Fireplace Repair
Faults tested with a meter, written up with each reading, and repaired once you approve the part and its price.
See the visit →Fireplace Remodel
Surround, hearth and mantel changes planned after an inspection, so the firebox behind the new face is sound.
See the visit →Pellet Stove Repair
A pellet stove run through a start cycle, each fault logged against the part behind it, and the vent pipe inspected.
See the visit →Wood Stove Repair
Door seals, baffles, firebrick and combustors replaced, with the stove pipe and its chimney connection written up.
See the visit →Gas Logs
A gas log set chosen after the flue and firebox pass inspection, fitted to the opening and tested for flame and draft.
See the visit →Chimney Seismic Retrofit
Older brick stacks rated for quake risk, then braced, strapped or rebuilt lighter above the roof, with options laid out from photos.
See the visit →Chimney Crown Repair
Cracked or thin crowns sealed or recast, with the top of the stack photographed before and after for the report.
See the visit →Dryer Vent Cleaning
Lint cleared from the dryer duct, airflow measured at the outlet, and the duct route written up with any damage.
See the visit →Chimney Liner Installation
A stainless flue liner matched to the appliance's vent size, run the full height and recorded on camera when done.
See the visit →Chimney Leak Repair
Leaks traced to their source with photos, then repaired at whichever crown, cap, flashing or brick let the water in.
See the visit →Chimney Waterproofing
Breathable repellent applied to sound brick once repairs are done, with the treated faces logged in the report.
See the visit →Chimney Damper Repair
Sticking, warped or rusted dampers repaired or replaced, with their condition photographed in the report.
See the visit →Chimney Chase Cover
Chase tops that hold water rated in the report, then replaced with a custom stainless cover once the framing is checked.
See the visit →